Industrial Competence.
Comprehensive Climate Control.
Our HVAC engineering disciplines map across the full building lifecycle — from initial thermodynamic load modeling to BAS-integrated smart climate delivery and certified energy performance sign-offs.
Technical Specializations
Variable Refrigerant Flow (VRF) Optimization
We engineer and right-size VRF multi-zone systems for commercial buildings, modulating refrigerant flow with precision to eliminate simultaneous heating/cooling conflicts and reduce energy consumption by 30–45%.
Building Automation Systems (BAS)
Full BACnet/IP and Modbus integration from the sensor node to the cloud dashboard. We design sequence of operations, control logic, and alarm protocols for complex multi-plant HVAC configurations.
Smart Air-Handling Delivery
Custom Air Handling Unit (AHU) specifications incorporating EC fan arrays, heat wheel energy recovery, and UV-C germicidal filtration. We deliver MERV-16 capable systems targeting WELL v2 air quality compliance.
Geothermal Heat Exchange Systems
We design and model closed-loop ground source heat pump systems using bore field thermal analysis software. Our ground loop sizing methodology integrates soil thermal conductivity testing for accurate peak load coverage.
Energy Modeling & Commissioning
We leverage EnergyPlus and eQUEST simulation platforms to validate design performance against Title 24, ASHRAE 90.1, and LEED v4.1 EQ baselines, providing third-party-validated energy model reports for code compliance.
Industrial Process Cooling
From data center precision cooling (CRAC/CRAH arrays) to heavy manufacturing heat rejection, we engineer glycol chilled water loops, evaporative cooling towers, and adiabatic pre-cooling systems for extreme thermal loads.
Variable Air Volume System Design
Our VAV design practice extends from block load calculations using ASHRAE Manual N methodology to custom terminal box scheduling programs integrated into your building's BAS. We model supply air temperatures, zone reheat sequences, and economizer lockout setpoints to achieve ASHRAE 90.1-2022 minimum thresholds.
Every VAV design ships with a stamped Mechanical Engineering Basis of Design (BOD) report and sequence of operations (SOO) document for construction-level coordination.
Start VAV AssessmentVAV Terminal Box Array Schematic
Building Automation & Controls Integration
We write and validate BAS sequence of operations for complex, multi-plant HVAC systems. Our controls engineers deliver native BACnet/IP programming using Niagara Framework (Tridium), Automated Logic, Schneider EcoStruxure, and Siemens Desigo CC platforms.
Integration services include fault detection and diagnostics (FDD) rule-set deployment, utility sub-metering integration, and LEED v4.1 Enhanced Commissioning documentation packages.
BAS Integration InquiryBAS Network Architecture Diagram
Geothermal Fluid Decarbonization Retrofits
Our geothermal engineering practice deploys closed-loop ground source heat pump (GSHP) systems as direct replacements for aging fossil fuel boiler and chiller plants. We perform on-site thermal response testing (TRT) to determine soil thermal conductivity and borehole resistance, then model full bore field layouts using advanced simulation software.
Projects include IRA Section 48C tax credit qualification documentation, state incentive stacking analysis, and utility grid impact studies — positioning clients for maximum decarbonization ROI.
Geothermal Feasibility StudyBore Field Loop Thermal Model